Web beta · by invitation

HVAC design on the drawing — sized as you draw it.

Draw the floor and Viszio MEP works it out as you go: each room's load, the ducts and the VRF or chilled-water pipework sized to ASHRAE, every fitting read off its table, and the Bill of quantities priced from your own rates.

Free during the betaRuns in the browserEnglish and FrenchKeeps working with no signal
mep.visziotech.com — ground floor, supply air
The Viszio MEP design canvas: a ground-floor supply-air system drawn on a plan, ducts coloured by their velocity, sizes and airflows on every run, and a panel listing what needs attention.
What it works out

The calculation sits under the drawing, not beside it.

Move a room, a duct or a unit and every number that depends on it follows — the load, the size, the pressure, the bill.

Room loads

Every room from the plan: walls and windows facing their real direction, people, lighting, equipment and outdoor air by the room's use.

ASHRAE Fundamentals · 62.1 · 90.1

Ductwork

Sized by velocity, friction or static regain, each fitting's loss off its table, the index run, the fan's external pressure, damper settings for balancing.

ASHRAE Duct Fitting Database · SMACNA

VRF and chilled water

Units placed in every room by its load, the copper or the flow and return routed and sized, one outdoor unit or chiller for the whole building on one riser.

Refnet sizing · pump head · condensate

What goes out

Plotted drawings, DXF and IFC, the calculation report, schedules in Excel, the commissioning sheet and the Bill of quantities.

PDF · DXF · IFC4 · XLSX
From the architect's plan

Rooms and their loads, straight off the drawing.

Load the architect's PDF, DXF or IFC model under the sheet and pick the rooms off it — one click inside each, or every room in one pass. Each goes onto the load schedule with its area and is shaded by its load.

  • Outside walls and windows read from the plan, facade by facade
  • Outdoor air checked against ASHRAE 62.1, room by room
  • The air balance through every door, with the undercut or grille it needs
Floor plan mode: eight rooms shaded by their cooling load in W/m², with the storey's rooms, areas and loads listed in a side panel.
On site

Commission it on a tablet.

Set the fan to its design airflow, tap each diffuser and type what the hood reads. It shows the share of design against your tolerance, names the reference terminal on each branch for proportional balancing, and moves on to the next.

  • Green inside the tolerance, red short, amber over — on the plan
  • The readings go straight onto the commissioning sheet
  • Works in a plant room with no signal
Commission mode: diffusers on the plan ringed green, red or amber by their measured airflow against design, and a panel taking the next reading.
Built for West Africa

Designed in Accra, for the jobs here.

Request access

Try the beta on your next job.

We're opening it to engineers a few at a time, so each one gets a proper hand. It's free while it's in beta.

  1. Tell us who you are. Name, company, email — and what you'd design with it.
  2. We add you, usually within one working day, and email you when you're in.
  3. Sign in at mep.visziotech.com with your email — a one-time code arrives in your inbox. No password to remember.
The one you'll sign in with.

We'll only contact you about the beta. See our privacy notice.

Questions

Before you ask.

Is it free?

Yes, while it's in beta. Drawings and documents exported from the beta carry a trial watermark; a company licence — clean drawings with your own title block — comes after.

Do I need to install anything?

No. It runs in Chrome or Edge on a laptop or a tablet. The first visit needs a connection to sign in; after that the app is kept on your computer and opens without one.

Where is my job kept?

In your own browser, on your own computer. Save writes a job file you keep, send or open on another machine — nothing is uploaded to us.

Which VRF catalogue does it use?

The beta sizes VRF on a typical heat-pump range, not any manufacturer's. You can load your own indoor units, fan coils and diffusers from a spreadsheet.

What about fire, plumbing and electrical?

The web beta is the HVAC design. The full suite — fire, plumbing, electrical and take-off — runs on Windows; ask us about it in the form.